Specifications
Velocity Range: 0 to 9,999 ft/min (0 to 50 m/s)
Velocity Accuracy: +/-3% of Reading or +/-3 ft/min (+/-0.015 m/s)
Temperature Range: 14 F to 140 F (-10 C to 60 C)
Temperature Accuracy: +/-0.5 F (+/-0.3 C)
Relative Humidity Range: 0 to 95% RH
Relative Humidity Accuracy: +/-3% RH
Duct Size: 1 to 500 inches (Increments of 0.1 inch); 2.5 to 1,270 centimeters (Increments of 0.1 centimeter)
Volumetric Flow Rate Range: Function of Velocity, Pressure, Duct Size & K Factor
Static/Differential Pressure Range: -15 to +15 inches H2O (-28.0 to +28.0 mm Hg, -3735 to +3735 Pa)
Static/Differential Pressure Accuracy: +/-1% of Reading +/-0.005 inches H2O (+/-0.01 mm Hg, +/-1 Pa)
Barometric Pressure Range: 20.36 to 36.648 inches Hg (517.15 to 930.87 mm Hg)
Barometric Pressure Accuracy: +/-2% of Reading
Data Log: 26,500+ Samples, 100 Test IDs, User-Selectable Interval: 1 Second to 1 Hour or Continuous
User-Selectable Time Constant
Power: Alkaline Battery
Weight: 0.8 lbs (0.36 kg)